Intesis DALI-2 Protocol Translator with - IN704DAL1280000

$1,047.00

Integrate any DALI/DALI-2 driver and DALI-2 light sensor or occupancy sensor with a Modbus BMS or any Modbus TCP controller with the IN704DAL1280000. This integration aims to make DALI devices and their data and resources accessible from a Modbus-based control system or device as if they were a part of the Modbus system and vice versa.

Model Number:


SKU: INS1D-61
MODEL NUMBER: IN704DAL1280000

Category:

Description

Integrate any DALI/DALI-2 driver and DALI-2 light sensor or occupancy sensor with a Modbus BMS or any Modbus TCP controller with the IN704DAL1280000. This integration aims to make DALI devices and their data and resources accessible from a Modbus-based control system or device as if they were a part of the Modbus system and vice versa.

IN704DAL1280000 Features and Benefits

Modbus support
The gateway supports the Modbus TCP protocol.

Up to five concurrent Modbus TCP clients supported
The gateway supports up to five simultaneous Modbus TCP clients.

DALI support
The gateway is DALI-2 certified and supports DALI/DALI-2 drivers and DALI-2 input devices: Push buttons, absolute input devices, and occupancy and light sensors.

Easy DALI commissioning/integration w/Intesis MAPS
Integration and DALI commissioning processes are managed via the Intesis MAPS configuration tool. Templates can be imported and reused as often as needed, significantly reducing commissioning time.

Local control options
Occupancy and light sensors, push buttons, and absolute inputs can be locally controlled from the gateway. The DALI standard device type for Energy and Diagnostic data has also been implemented.

Color control
RGB and tunable white controls are available in Intesis MAPS, to cover the demand for Human Centric Lighting.

Max 64 drivers/ballasts + 64 DALI-2 input devices per channel
Supports up to 64 drivers/ballasts + 64 DALI-2 input devices (sensors/push buttons/absolute inputs) per channel.

Signals and power
A DALI power supply is integrated into the gateway, so no external DALI power supply is required. Up to 10,000 signals can be defined in total, with a guaranteed output current of 230 mA.

Additional information

Manufacturer

Product Documents

No additional documents or details.

The Engenuity Difference

Headphones Icon

FREE TECH SUPPORT

No need to worry about using new products; we are here to help and support everything we sell.

Credit Card Icon

SHIPPING PERFORMANCE

You need shipping done your way. Fast. Accurate, tracked, and with flexibility.

Truck / Delivery Icon

KITTING LOGISTICS

Procurement and deployment can get complicated; let our 30 years of experience solve your most challenging logistics issues.

Shipping Icon

CREDIT ACCOUNTS

Cash flow and payment timing can shape a project. Talk to our credit team to help turn your project into a financial success.