{"product_id":"fs-ez1-mbus-md-bac","title":"FS-EZ1-MBUS-MD-BAC EZ Gateway MBUS-Modbus-BACnet 16 Slaves","description":"With the FS-EZ1-MBUS-MD-BAC EZ Gateway M-Bus to Modbus \u0026amp; BACnet, the integrator or contractor does not need to be a protocol expert, and can minimize configuration and commissioning time, while also reducing ongoing operating and maintenance costs.\n\nThe FS-EZ1-MBUS-MD-BAC EZ Gateway M-Bus to Modbus \u0026amp; BACnet combines field-hardened M-Bus, Modbus and BACnet protocol drivers with an easy to use configuration interface that, once configured, allows M-Bus devices to be presented as virtual BACnet devices which simplifies commissioning, configuration and troubleshooting. The intuitive web-based interface allows configurations to be built in the field or in the office. Additionally, the configuration profiles can be downloaded and then uploaded to other FieldServer M-Bus applications, simplifying the commissioning and integration process on repeatable applications.\n\n\u003cstrong\u003e1. M-BUS INTEROPERABILITY\u003c\/strong\u003e\n\u003cul\u003e\n \t\u003cli\u003eM-Bus Explorer discovers all M-Bus devices in the network, shows the manufacturer details as well as available points, and offers one-click profile generation\u003c\/li\u003e\n \t\u003cli\u003eProfile Loader enables efficient profile editing, exporting and importing\u003c\/li\u003e\n \t\u003cli\u003eCommunication between devices with different baud rates at the same time\u003c\/li\u003e\n \t\u003cli\u003eVirtual nodes allow each M-Bus device connected to a single EZ Gateway to be seen as a separate device on the BACnet network\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cstrong\u003e2. BACNET COV\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul\u003e\n \t\u003cli\u003eUse the Change of Value (CoV) setting to reduce the amount of BACnet data overhead to allow network traffic to be less congested by transmitting data only when detecting an M-Bus device status change\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cstrong\u003e3. REMOTE ACCESS AND SUPPORT\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul\u003e\n \t\u003cli\u003eAll FieldServer gateways come with Remote Access support.  Once registerd to the MSA Grid, use the Remote Access capability to attach to the FieldServer gateway to monitor, maintain and troubleshoot installed equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cstrong\u003e4. BACNET BBMD SERVER SUPPORT\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul\u003e\n \t\u003cli\u003eFor connecting to remote BACnet networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cstrong\u003e5. REMOTE DIAGNOSTICS\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul\u003e\n \t\u003cli\u003eDiagnostics of the devices connected to the network is available via Web Interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cstrong\u003e6. MSA GRID SUPPORT\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul\u003e\n \t\u003cli\u003eRegister your EZ Gateway to the MSA Grid interface for remote access to local applications, configuration, and device management\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\n\u003cul\u003e\n \t\u003cli\u003e9-30V DC or 12-24V AC\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eCurrent draw @ 12V\u003c\/strong\u003e:\n\u003cul\u003e\n \t\u003cli\u003e1 Slave: 580 mA\u003c\/li\u003e\n \t\u003cli\u003e64 Slaves: 980 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eEnclosure   \u003c\/strong\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 4.5 x 2.9 x 1.6 in. (11.5 x 7.4 x 4.1 cm)\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.4 lbs (0.2 Kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eEnvironmental \u003c\/strong\u003e\n\u003cul\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40 to 75C (-40 to 167F))\u003c\/li\u003e\n \t\u003cli\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 5-90% non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eOther  \u003c\/strong\u003e\n\u003cul\u003e\n \t\u003cli\u003eConfiguration\/Diagnostic utilities\u003c\/li\u003e\n \t\u003cli\u003eTable, wall, or DIN rail mount\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eCommunication   \u003c\/strong\u003e\n\u003cul\u003e\n \t\u003cli\u003eBaud: 2400, 4800, 9600, 19200, 38400\u003c\/li\u003e\n \t\u003cli\u003eStart Bit: 7, 8\u003c\/li\u003e\n \t\u003cli\u003eEthernet: 10\/100 BaseT MDIX\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50682373374210,"sku":"MSA00013","price":982.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/FS-EZ-MBUS-MOD-BAC-360-03.jpg?v=1792008736","url":"https:\/\/engenuity.com\/products\/fs-ez1-mbus-md-bac","provider":"Engenuity Systems","version":"1.0","type":"link"}