{"title":"Intesis","description":"","products":[{"product_id":"inmbsdai001i000-daikin-ac-domestic-units-to-modbus-rtu-interface","title":"INMBSDAI001I000 Daikin AC Domestic Units to Modbus RTU Interface","description":"\u003cp\u003eModbus RTU - DAIKIN AC. Domestic Lines\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732293488898,"sku":"INS1A-59","price":328.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/INMBSDAI001I000-front.png?v=1792017494"},{"product_id":"inknxdai001r000-daikin-vrv-and-sky-systems-to-knx-interface","title":"INKNXDAI001R000 Daikin VRV and Sky Systems to KNX Interface","description":"\u003cp\u003eThe Daikin-KNX INKNXDAI001R000 interface allows full bidirectional communication between Daikin VRV and Sky systems and KNX installations. It connects directly to the indoor unit and delivers complete interoperability with KNX.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eETS configuration\u003c\/strong\u003e\u003cbr\u003eThe interface is configured using the ETS standard configuration tool software.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCompatible with all KNX thermostats in the market\u003c\/strong\u003e\u003cbr\u003eAll the required DPT objects to be compatible with all KNX thermostats in the market are available.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMultiple energy efficiency functions available\u003c\/strong\u003e\u003cbr\u003eTimeout, open window, or occupancy energy-saving functions are available to reduce energy costs.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSmooth KNX thermostat integration\u003c\/strong\u003e\u003cbr\u003eKNX thermostats are allowed to control the AC unit via the thermostat's temperature sensor.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTotal unit control and monitoring from KNX\u003c\/strong\u003e\u003cbr\u003eThrough internal variables, running hours counter (for maintenance purposes), and error indication.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eUp to five scenes saved\/executed from KNX\u003c\/strong\u003e\u003cbr\u003eUp to five scenes can be saved and executed from KNX.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC unit control by both remote controller and KNX\u003c\/strong\u003e\u003cbr\u003eThe AC unit can be simultaneously controlled by the manufacturer's remote controller and KNX.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCompact dimensions, allowing inside installation\u003c\/strong\u003e\u003cbr\u003eThe interface can be quickly installed inside the AC unit thanks to its reduced dimensions.\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732293521666,"sku":"INS1A-06","price":273.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/INKNXDAI001R000_side.avif?v=1792017493"},{"product_id":"inbacpan001r100-panasonic-ecoi-and-paci-systems-to-bacnet-mstp-interface","title":"INBACPAN001R100 Panasonic ECOi and PACi Systems to BACnet MSTP Interface","description":"\u003cp\u003ePanasonic ECOi and PACi systems to BACnet MSTP Interface - 1 unit\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732293554434,"sku":"INS1B-26","price":328.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/inbacpan001r100_front_w658.jpg?v=1792017494"},{"product_id":"inwmpmit001i000-mitsubishi-electric-to-wifi","title":"INWMPMIT001I000 Mitsubishi Electric to WiFi","description":"\u003cp\u003eWi-fi - MITSUBISHI AC. Domestic, Mr. Sli\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732293587202,"sku":"INS1B-57","price":328.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/inknxmit001i000_side_w658.jpg?v=1792017495"},{"product_id":"inbacmid001i100-midea-commercial-vrf-systems-to-bacnet-mstp","title":"INBACMID001I100 Midea Commercial \u0026 VRF Systems to BACnet MSTP","description":"\u003cp\u003eMidea Commercial \u0026amp; VRF to BACnet MSTP\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732293685506,"sku":"INS1D-59","price":328.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/inbacmid001i100_front_658.jpg?v=1792017497"},{"product_id":"inmbsocp0010100-ocpp-to-modbus-tcp-rtu-server-gateway","title":"INMBSOCP0010100 Ocpp to Modbus TCP \u0026 RTU Server Gateway","description":"\u003cp\u003eOCPP-Modbus TCP \u0026amp; RTU Server Gateway 1D\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732293718274,"sku":"INS1D-32","price":713.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/inmbsocp0010100.jpg?v=1792017497"},{"product_id":"inmbsfgl001r000-fujitsu-rac-and-vrf-systems-to-modbus-rtu-interface","title":"INMBSFGL001R000 Fujitsu RAC and VRF Systems to Modbus RTU Interface","description":"\u003cp\u003eModbus RTU - FUJITSU AC. Commercial \u0026amp; VR\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732294275330,"sku":"INS1A-61","price":328.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/INMBSFGL001R000-front.png?v=1792017498"},{"product_id":"inwmpmhi001r000-mitsubishi-heavy-industries-fd-and-vrf-systems-to-wifi","title":"INWMPMHI001R000 Mitsubishi Heavy Industries FD and VRF Systems to WiFi","description":"\u003cp\u003eWi-fi - MITSUBISHI HEAVY INDUSTRIES AC.\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732294406402,"sku":"INS1B-59","price":328.0,"currency_code":"USD","in_stock":true}]},{"product_id":"inbactos001r000-toshiba-vrf-and-digital-systems-to-bacnet-ip-mstp-interface","title":"INBACTOS001R000 Toshiba VRF and Digital Systems to BACnet IP\/MSTP Interface","description":"\u003cp\u003eBACnet - TOSHIBA AC. Commercial \u0026amp; VRF li\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732294439170,"sku":"INS1B-27","price":389.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/inbactos001r000_front_w658.jpg?v=1792017499"},{"product_id":"inmbsocp0200100-ocpp-to-modbus-tcp-rtu-server-gateway","title":"INMBSOCP0200100 Ocpp to Modbus TCP \u0026 RTU Server Gateway","description":"\u003cp\u003eOCPP-Modbus TCP \u0026amp; RTU Server Gateway 20D\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732294537474,"sku":"INS1D-33","price":2027.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/MFG_INMBSOCP0010100.jpg?v=1792017499"},{"product_id":"inknxdai001r100-daikin-vrv-and-sky-systems-to-knx-interface","title":"INKNXDAI001R100 Daikin VRV and Sky Systems to KNX Interface","description":"KNX - DAIKIN AC. SKY Air and VRV system\n\nThe Daikin-KNX INKNXDAI001R100 interface allows full bidirectional communication between Daikin VRV and Sky systems and KNX installations. It has four potential-free binary inputs to integrate external devices (such as window contacts or presence detectors), with the corresponding internal functions available to help improve energy efficiency.\n\u003ch3\u003eFeatures and benefits\u003c\/h3\u003e\n\u003cstrong\u003eETS configuration\u003c\/strong\u003e - The interface is configured using the ETS standard configuration tool software.\n\n\u003cstrong\u003eCompatible with all KNX thermostats in the market \u003c\/strong\u003e- All the required DPT objects to be compatible with all KNX thermostats in the market are available.\n\n\u003cstrong\u003eMultiple energy efficiency functions available \u003c\/strong\u003e- Timeout, open window, or occupancy energy-saving functions are available to reduce energy costs.\n\n\u003cstrong\u003eSmooth KNX thermostat integration\u003c\/strong\u003e - KNX thermostats are allowed to control the AC unit via the thermostat's temperature sensor.\n\n\u003cstrong\u003eTotal unit control and monitoring from KNX\u003c\/strong\u003e - Through internal variables, running hours counter (for maintenance purposes), and error indication.\n\n\u003cstrong\u003eUp to five scenes saved\/executed from KNX\u003c\/strong\u003e - Up to five scenes can be saved and executed from KNX.\n\n\u003cstrong\u003eAC unit control by both remote controller and KNX\u003c\/strong\u003e - The AC unit can be simultaneously controlled by the manufacturer's remote controller and KNX.\n\n\u003cstrong\u003eCompact dimensions, allowing inside installation\u003c\/strong\u003e - The interface can be quickly installed inside the AC unit thanks to its reduced dimensions.\n\n \n\n\u003csection id=\"product_features\" class=\"bg-almost-white mt:bg-transparent border border-marine-grey-20 mt:border-none p-16 mt:p-0 mb-16\" data-heading=\"Features and benefits\"\u003e\n\u003cp class=\"text-textbody-80 mb-0\"\u003e\u003c\/p\u003e\n\n\u003c\/section\u003e\u003csection class=\"2lg:pt-8 pt-4 2lg:pr-24 2lg:pb-8 pb-4 2lg:pl-24 container grid grid-cols-12 mt:grid-cols-1 grid-gap\"\u003e\n\u003cdiv class=\"col-span-12 mt:col-span-full [\u0026amp;\u0026gt;div]:w-full\" style=\"border: 0px solid #e5e7eb; box-sizing: border-box; scrollbar-color: auto; scrollbar-width: auto; --tw-border-spacing-x: 0; --tw-border-spacing-y: 0; --tw-translate-x: 0; --tw-translate-y: 0; --tw-rotate: 0; --tw-skew-x: 0; --tw-skew-y: 0; --tw-scale-x: 1; --tw-scale-y: 1; --tw-scroll-snap-strictness: proximity; --tw-ring-offset-width: 0px; --tw-ring-offset-color: #fff; --tw-ring-color: rgba(59,130,246,.5); --tw-ring-offset-shadow: 0 0 #0000; --tw-ring-shadow: 0 0 #0000; --tw-shadow: 0 0 #0000; --tw-shadow-colored: 0 0 #0000; scroll-margin-top: 80px; grid-column: span 12 \/ span 12;\"\u003e\n\u003cdiv class=\"grid grid-cols-2 mt:grid-cols-1 gap-6 md:gap-8 lg:gap-4 desktop:gap-8 \"\u003e\n\u003cdiv class=\" flex flex-col\"\u003e\u003cpicture class=\"flex\"\u003e\u003csource srcset=\"https:\/\/media.hms-networks.com\/image\/upload\/c_fill,g_auto,f_auto,q_auto,dpr_auto,e_sharpen,w_520\/v1646222948\/Graphics\/Hardware_Meets_Software_2.jpg?sf_dm_key=Uoa847vHgP7e9iODfIpGjhg0M4n-nCIlcqiLJU8nL9E1\" media=\"(max-width: 425px)\"\u003e\u003csource srcset=\"https:\/\/media.hms-networks.com\/image\/upload\/c_fill,g_auto,f_auto,q_auto,dpr_auto,e_sharpen,w_1060\/v1646222948\/Graphics\/Hardware_Meets_Software_2.jpg?sf_dm_key=Uoa847vHgP7e9iODfIpGjhg0M4n-nCIlcqiLJU8nL9E1\" media=\"(max-width: 1024px)\"\u003e\u003c\/source\u003e\u003c\/picture\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732294603010,"sku":"INS1A-07","price":328.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/INKNXDAI001R100_side.avif?v=1792017501"},{"product_id":"in703dal0640000-intesis-dali-2-protocol-translator","title":"IN703DAL0640000 Intesis DALI-2 Protocol Translator","description":"\u003cp\u003eIntegrate any DALI\/DALI-2 driver and DALI-2 input devices like light or occupancy sensors with a BACnet BMS or any BACnet\/IP or BACnet MS\/TP controller with the IN703DAL0640000. This integration aims to make DALI devices and their data and resources accessible from a BACnet-based control system or device as if they were a part of the BACnet system and vice versa.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eBACnet support\u003c\/strong\u003e\u003cbr\u003eThe gateway is BTL certified and supports both BACnet\/IP and BACnet MS\/TP protocols.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eBACnet advanced features\u003c\/strong\u003e\u003cbr\u003eBACnet's advanced features, such as calendars, trend logs, schedules, and more, are available.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDALI support\u003c\/strong\u003e\u003cbr\u003eThe gateway is DALI-2 certified and supports DALI\/DALI-2 drivers and DALI-2 input devices: Push buttons, absolute input devices, and occupancy and light sensors.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eEasy DALI commissioning\/integration w\/Intesis MAPS\u003c\/strong\u003e\u003cbr\u003eIntegration and DALI commissioning processes are managed via the Intesis MAPS configuration tool. Templates can be imported and reused as often as needed, significantly reducing commissioning time.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eLocal control options\u003c\/strong\u003e\u003cbr\u003eOccupancy and light sensors, push buttons, and absolute inputs can be locally controlled from the gateway. The DALI standard device type for Energy and Diagnostic data has also been implemented.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eColor control\u003c\/strong\u003e\u003cbr\u003eRGB and tunable white controls are available in Intesis MAPS, to cover the demand for Human Centric Lighting.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMax 64 drivers\/ballasts + 64 DALI-2 input devices\u003c\/strong\u003e\u003cbr\u003eSupports up to 64 drivers\/ballasts + 64 DALI-2 input devices (sensors\/push buttons\/absolute inputs).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSignals and power\u003c\/strong\u003e\u003cbr\u003eA DALI power supply is integrated into the gateway, so no external power supply is required. Up to 10,000 signals can be defined in total, with a guaranteed output current of 230 mA.\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732294635778,"sku":"INS1D-60","price":876.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/700_Series_BTLUL_side.avif?v=1792017501"},{"product_id":"inmbshit001r000-hitachi-commercial-vrf-systems-to-modbus-rtu-interface","title":"INMBSHIT001R000 Hitachi Commercial \u0026 VRF Systems to Modbus RTU Interface","description":"\u003cp\u003eModbus RTU - HITACHI AC. Commercial Line\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732295160066,"sku":"INS1A-62","price":328.0,"currency_code":"USD","in_stock":true}]},{"product_id":"inwmppan001i000-panasonic-etherea-ac-units-to-wifi","title":"INWMPPAN001I000 Panasonic Etherea AC Units to WiFi","description":"\u003cp\u003eWi-fi - PANASONIC AC. Domestic Lines\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732295291138,"sku":"INS1B-60","price":328.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/panasonic-ecoi-paci-bacnet-ip-mstp-interface.jpg?v=1792017502"},{"product_id":"in485uni001i100-universal-ir-air-conditioner-to-bacnet-mstp-modbus-rtu","title":"IN485UNI001I100 Universal IR Air Conditioner to BACnet MSTP \/ Modbus RTU","description":"\u003cp\u003eUniversal IR Air Conditioner to BACnet MSTP \/ Modbus RTU - 1 unit\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732295323906,"sku":"INS1D-35","price":328.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/in485uni001i000_front_btl.jpg?v=1792017502"},{"product_id":"inknxfgl001r000-fujitsu-rac-and-vrf-systems-to-knx-interface","title":"INKNXFGL001R000 Fujitsu RAC and VRF Systems to KNX Interface","description":"\u003cp\u003e\u003cstrong\u003eETS configuration\u003c\/strong\u003e\u003cbr\u003eThe interface is configured using the ETS standard configuration tool software.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCompatible with all KNX thermostats in the market\u003c\/strong\u003e\u003cbr\u003eAll the required DPT objects to be compatible with all KNX thermostats in the market are available.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMultiple energy efficiency functions available\u003c\/strong\u003e\u003cbr\u003eTimeout, open window, or occupancy energy-saving functions are available to reduce energy costs.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSmooth KNX thermostat integration\u003c\/strong\u003e\u003cbr\u003eKNX thermostats are allowed to control the AC unit via the thermostat's temperature sensor.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTotal unit control and monitoring from KNX\u003c\/strong\u003e\u003cbr\u003eThrough internal variables, running hours counter (for maintenance purposes), and error indication.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eUp to five scenes saved\/executed from KNX\u003c\/strong\u003e\u003cbr\u003eUp to five scenes can be saved and executed from KNX.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC unit control by both remote controller and KNX\u003c\/strong\u003e\u003cbr\u003eThe AC unit can be simultaneously controlled by the manufacturer's remote controller and KNX.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCompact dimensions, allowing inside installation\u003c\/strong\u003e\u003cbr\u003eThe interface can be quickly installed inside the AC unit thanks to its reduced dimensions.\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732295389442,"sku":"INS1A-08","price":328.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/INKNXFGL001R000_side.avif?v=1792017503"},{"product_id":"in701knx1000000-intesis-protocol-translator-with-knx","title":"IN701KNX1000000 Intesis Protocol Translator with KNX","description":"\u003cp\u003eIntesis protocol translator with KNX, Serial and IP support - 100 points\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732295422210,"sku":"INS1B-28","price":1047.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/701knx_inknxbacxxx0000.jpg?v=1792017504"},{"product_id":"in704dal1280000-intesis-dali-2-protocol-translator-with-ip-support","title":"IN704DAL1280000 Intesis DALI-2 Protocol Translator with IP Support","description":"Integrate any DALI\/DALI-2 driver and DALI-2 light sensor or occupancy sensor with a Modbus BMS or any Modbus TCP controller with the IN704DAL1280000. This integration aims to make DALI devices and their data and resources accessible from a Modbus-based control system or device as if they were a part of the Modbus system and vice versa.\n\u003ch5\u003e\u003cstrong\u003eIN704DAL1280000 Features and Benefits\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cstrong\u003eModbus support\u003c\/strong\u003e\nThe gateway supports the Modbus TCP protocol.\n\n\u003cstrong\u003eUp to five concurrent Modbus TCP clients supported\u003c\/strong\u003e\nThe gateway supports up to five simultaneous Modbus TCP clients.\n\n\u003cstrong\u003eDALI support\u003c\/strong\u003e\nThe gateway is DALI-2 certified and supports DALI\/DALI-2 drivers and DALI-2 input devices: Push buttons, absolute input devices, and occupancy and light sensors.\n\n\u003cstrong\u003eEasy DALI commissioning\/integration w\/Intesis MAPS\u003c\/strong\u003e\nIntegration and DALI commissioning processes are managed via the Intesis MAPS configuration tool. Templates can be imported and reused as often as needed, significantly reducing commissioning time.\n\n\u003cstrong\u003eLocal control options\u003c\/strong\u003e\nOccupancy and light sensors, push buttons, and absolute inputs can be locally controlled from the gateway. The DALI standard device type for Energy and Diagnostic data has also been implemented.\n\n\u003cstrong\u003eColor control\u003c\/strong\u003e\nRGB and tunable white controls are available in Intesis MAPS, to cover the demand for Human Centric Lighting.\n\n\u003cstrong\u003eMax 64 drivers\/ballasts + 64 DALI-2 input devices per channel\u003c\/strong\u003e\nSupports up to 64 drivers\/ballasts + 64 DALI-2 input devices (sensors\/push buttons\/absolute inputs) per channel.\n\n\u003cstrong\u003eSignals and power\u003c\/strong\u003e\nA DALI power supply is integrated into the gateway, so no external DALI power supply is required. Up to 10,000 signals can be defined in total, with a guaranteed output current of 230 mA.","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732295487746,"sku":"INS1D-61","price":1126.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/700_Series_UL_side.avif?v=1792017505"},{"product_id":"inmbshis001r000-hisense-vrf-systems-to-modbus-rtu-interface","title":"INMBSHIS001R000 Hisense VRF Systems to Modbus RTU Interface","description":"\u003cp\u003eModbus RTU - HISENSE AC. Commercial Line\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732295880962,"sku":"INS1A-63","price":328.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/inmbshis001r000_front_w658.jpg?v=1792017508"},{"product_id":"in485fgl001i000-fujitsu-rac-and-vrf-systems-to-bacnet-mstp-modbus-rtu-interface","title":"IN485FGL001I000 Fujitsu RAC and VRF Systems to BACnet MSTP \/ Modbus RTU Interface","description":"\u003cp\u003eFujitsu RAC and VRF systems to BACnet MSTP \/ Modbus RTU Interface - 1 unit\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732296044802,"sku":"INS1D-36","price":328.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/inmbsfgl001i000_side_w658.jpg?v=1792017510"},{"product_id":"inwmppan001r000-panasonic-ecoi-and-paci-systems-to-wifi","title":"INWMPPAN001R000 Panasonic ECOi and PACi Systems to WiFi","description":"\u003cp\u003eWi-fi - PANASONIC AC. ECOi \u0026amp; PACi lines\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732296110338,"sku":"INS1B-62","price":328.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/inwmpxxx001r000-side_w658.jpg?v=1792017510"},{"product_id":"in701knx2500000-intesis-protocol-translator-with-knx","title":"IN701KNX2500000 Intesis Protocol Translator with KNX","description":"\u003cp\u003eIntesis protocol translator with KNX, Serial and IP support - 250 points\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732296143106,"sku":"INS1B-29","price":1579.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/700-series_front-BTL-UL.jpg?v=1792017511"},{"product_id":"in770air00mo000-intesis-multi-brand-ac-interface-with-knx","title":"IN770AIR00MO000 Intesis Multi-Brand AC Interface with KNX","description":"Introducing the Intesis IN770AIR00MO000, a cutting-edge air conditioning control solution designed to seamlessly integrate your HVAC system with modern building automation protocols. This versatile gateway ensures efficient and reliable communication between your air conditioning units and various control systems, optimizing both performance and energy consumption. Supports multiple protocols, including Modbus, BACnet, and KNX, allowing for flexible integration with existing building management systems.\n\u003cp data-start=\"1112\" data-end=\"1449\"\u003eThe Intesis IN770AIR00MO000 is engineered for professionals seeking a reliable and efficient solution to integrate air conditioning systems within smart building infrastructures. Its comprehensive protocol support and user-centric design make it an ideal choice for enhancing HVAC control and achieving optimal indoor climate management.\u003c\/p\u003e\n\u003cp data-start=\"1451\" data-end=\"1590\"\u003eUpgrade your building's HVAC integration with the Intesis IN770AIR00MO000 and experience the benefits of advanced connectivity and control.\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732296241410,"sku":"INS1D-62","price":3912.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/700_Series_UL_side_d160c5be-c328-4600-ab91-d212b2c918eb.avif?v=1792017513"},{"product_id":"inknxhit001a000-hitachi-air-to-water-to-knx-interface","title":"INKNXHIT001A000 Hitachi Air to Water to KNX Interface","description":"\u003cp\u003e\u003cstrong\u003eETS configuration\u003c\/strong\u003e\u003cbr\u003eThe interface is configured using the ETS standard configuration tool software.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCompatible with all KNX thermostats in the market\u003c\/strong\u003e\u003cbr\u003eAll the required DPT objects to be compatible with all KNX thermostats in the market are available.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSmooth KNX thermostat integration\u003c\/strong\u003e\u003cbr\u003eKNX thermostats are allowed to control the AC unit via the thermostat's temperature sensor.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC unit control by both remote controller and KNX\u003c\/strong\u003e\u003cbr\u003eThe AC unit can be simultaneously controlled by the manufacturer's remote controller and KNX.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAnti-legionella activation\/deactivation function\u003c\/strong\u003e\u003cbr\u003eAn Anti-legionella function is available and can be easily activated or deactivated.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCompact dimensions, allowing inside installation\u003c\/strong\u003e\u003cbr\u003eThe interface can be quickly installed inside the AW unit thanks to its reduced dimensions.\u003c\/p\u003e\u003cp\u003eHitachi Air to Water to KNX Interface - 1 unit INKNXHIT001A000\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732296372482,"sku":"INS1A-09","price":328.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/INKNXHIT001A000_side.avif?v=1792017516"},{"product_id":"inmbslge001r000-lg-vrf-systems-to-modbus-rtu-interface","title":"INMBSLGE001R000 LG VRF Systems to Modbus RTU Interface","description":"\u003cp\u003eModbus RTU - LG AC  Commercial \u0026amp; VRF lin\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732296798466,"sku":"INS1A-68","price":328.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/inmbslge001r000_front_w658.jpg?v=1792017505"},{"product_id":"inwmptos001r000-toshiba-vrf-and-digital-systems-to-wifi","title":"INWMPTOS001R000 Toshiba VRF and Digital Systems to WiFi","description":"\u003cp\u003eWi-fi - TOSHIBA AC. Commercial \u0026amp; VRF Lin\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732297027842,"sku":"INS1B-63","price":328.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/inknxtos001r000_side_w658.jpg?v=1792017507"},{"product_id":"inknxlge001r000-lg-vrf-systems-to-knx-interface-with-binary-inputs","title":"INKNXLGE001R000 LG VRF Systems to KNX Interface with Binary Inputs","description":"\u003cp\u003eLG VRF systems to KNX Interface with binary inputs - 1 unit\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732297060610,"sku":"INS1D-39","price":328.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/inknxlge001r000_front_w658.jpg?v=1792017507"},{"product_id":"in701knx6000000-intesis-protocol-translator-with-knx","title":"IN701KNX6000000 Intesis Protocol Translator with KNX","description":"\u003cp\u003eIntesis protocol translator with KNX, Serial and IP support - 600 points\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732297191682,"sku":"INS1B-30","price":2012.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/700-series-protocol-translator-and-ac-interfaces-showcase.png?v=1792017508"},{"product_id":"in770air00so000-intesis-multi-brand-ac-interface-with-knx","title":"IN770AIR00SO000 Intesis Multi-Brand AC Interface with KNX","description":"\u003cp\u003eSamsung NASA VRF systems to WMP Interfac\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732297355522,"sku":"INS1D-63","price":2331.0,"currency_code":"USD","in_stock":true}]},{"product_id":"inknxhit001r000-hitachi-commercial-vrf-systems-to-knx-interface","title":"INKNXHIT001R000 Hitachi Commercial \u0026 VRF Systems to KNX Interface","description":"\u003cp\u003e\u003cstrong\u003eETS configuration\u003c\/strong\u003e\u003cbr\u003eThe interface is configured using the ETS standard configuration tool software.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCompatible with all KNX thermostats in the market\u003c\/strong\u003e\u003cbr\u003eAll the required DPT objects to be compatible with all KNX thermostats in the market are available.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMultiple energy efficiency functions available\u003c\/strong\u003e\u003cbr\u003eTimeout, open window, or occupancy energy-saving functions are available to reduce energy costs.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSmooth KNX thermostat integration\u003c\/strong\u003e\u003cbr\u003eKNX thermostats are allowed to control the AC unit via the thermostat's temperature sensor.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTotal unit control and monitoring from KNX\u003c\/strong\u003e\u003cbr\u003eThrough internal variables, running hours counter (for maintenance purposes), and error indication.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eUp to five scenes saved\/executed from KNX\u003c\/strong\u003e\u003cbr\u003eUp to five scenes can be saved and executed from KNX.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC unit control by both remote controller and KNX\u003c\/strong\u003e\u003cbr\u003eThe AC unit can be simultaneously controlled by the manufacturer's remote controller and KNX.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCompact dimensions, allowing inside installation\u003c\/strong\u003e\u003cbr\u003eThe interface can be quickly installed inside the AC unit thanks to its reduced dimensions.\u003c\/p\u003e\u003cp\u003eHitachi Commercial \u0026amp; VRF systems to KNX Interface with BI - 1 unit INKNXHIT001R000\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732297584898,"sku":"INS1A-10","price":328.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/INKNXXXX001R000_side.avif?v=1792017514"},{"product_id":"inmbsmit001i000-mitsubishi-electric-to-modbus-rtu-interface","title":"INMBSMIT001I000 Mitsubishi Electric to Modbus RTU Interface","description":"\u003cp\u003eModbus RTU - MITSUBISHI ELECTRIC AC. Dom\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732297650434,"sku":"INS1A-73","price":328.0,"currency_code":"USD","in_stock":true}]},{"product_id":"in485mit001i000-mitsubishi-electric-to-bacnet-mstp-interface","title":"IN485MIT001I000 Mitsubishi Electric to BACnet MSTP Interface","description":"\u003cp\u003eMitsubishi Electric to BACnet MSTP interface - 1 unit\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732297978114,"sku":"INS1C-19","price":328.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/inmbsmit001i000_front_w658.jpg?v=1792017517"},{"product_id":"in485hit001r000-hitachi-commercial-vrf-systems-to-bacnet-mstp-modbus-rtu-interface","title":"IN485HIT001R000 Hitachi Commercial \u0026 VRF Systems to BACnet MSTP \/ Modbus RTU Interface","description":"\u003cp\u003eHitachi Com \u0026amp; VRF sys to BACnet MSTP\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732298043650,"sku":"INS1D-41","price":328.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/in485hit001r100_front-btl.png?v=1792017519"},{"product_id":"in701knx1k20000-intesis-protocol-translator-with-knx","title":"IN701KNX1K20000 Intesis Protocol Translator with KNX","description":"\u003cp\u003eIntesis protocol translator with KNX, Serial and IP support - 1200 points\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732298240258,"sku":"INS1B-31","price":2940.0,"currency_code":"USD","in_stock":true}]},{"product_id":"in771air00lo000-intesis-multi-brand-ac-interface-with-knx","title":"IN771AIR00LO000 Intesis Multi-Brand AC Interface with KNX","description":"\u003cp\u003eThe Panasonic application has been specially designed to allow bidirectional control and monitoring of Panasonic ECOi, PACi, ECOg \/ PAC, VRF systems from a KNX installation. The solution allows the integration of up to 128 indoor units from a single interface.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKNX standard datapoints (DPTs) support\u003c\/strong\u003e\u003cbr\u003eKNX standard datapoints (DPTs) are supported, guaranteeing a simple KNX device\/system integration.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDirect access to the outdoor unit\u003c\/strong\u003e\u003cbr\u003eConnection is simple, as the interface connects directly to the outdoor unit’s communication bus.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAutomatic identification\u003c\/strong\u003e\u003cbr\u003eA scan function is available for automatic identification of the units present in the VRF system.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOutdoor unit signals\u003c\/strong\u003e\u003cbr\u003eSignals assigned to the outdoor unit are available to be used in the integration.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIndividual indoor unit energy consumption signals\u003c\/strong\u003e\u003cbr\u003eEnergy consumption signals from each indoor unit are available, so they can be checked individually.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDatapoint support\u003c\/strong\u003e\u003cbr\u003eA wide range of monitoring and control datapoints is available.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCommissioning-friendly approach with Intesis MAPS\u003c\/strong\u003e\u003cbr\u003eTemplates can be imported and reused as often as needed, significantly reducing commissioning time.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eConfiguration tool and interface automatic updates\u003c\/strong\u003e\u003cbr\u003eBoth the Intesis MAPS configuration tool and the interface's firmware can receive automatic updates.\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732298273026,"sku":"INS1D-64","price":4580.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/700_Series_UL_side_a085d6f1-1aaa-44ac-ba7f-10b2eda9de2c.avif?v=1792017523"},{"product_id":"inknxhis001r000-hisense-vrf-systems-to-knx-interface-with-binary-inputs","title":"INKNXHIS001R000 Hisense VRF Systems to KNX Interface with Binary Inputs","description":"\u003cp\u003eKNX - HISENSE AC Commercial Lines (PAC,\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732298436866,"sku":"INS1A-11","price":328.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/inknxhis001r000_side_w658.jpg?v=1792017528"},{"product_id":"inmbsmhi001r000-mitsubishi-heavy-industries-fd-and-vrf-systems-to-modbus-rtu-interface","title":"INMBSMHI001R000 Mitsubishi Heavy Industries FD and VRF Systems to Modbus RTU Interface","description":"\u003cp\u003eModbus RTU - MITSUBISHI HEAVY INDUSTRIES\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732298502402,"sku":"INS1A-79","price":328.0,"currency_code":"USD","in_stock":true}]},{"product_id":"inknxmeb0100000-m-bus-to-knx-tp-gateway","title":"INKNXMEB0100000 M-BUS to KNX TP Gateway","description":"\u003cp\u003e\u003cstrong\u003eEasy commissioning\u003c\/strong\u003e\u003cbr\u003eIntegration and M-BUS commissioning processes are managed via the Intesis MAPS configuration tool.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSupport for KNX TP devices\u003c\/strong\u003e\u003cbr\u003eThe gateway supports KNX TP (twisted pair) devices.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eControl up to 3000 KNX communication objects\u003c\/strong\u003e\u003cbr\u003eUp to 3000 KNX communication objects can be controlled by the gateway.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAutomatic meter detection and register discovery\u003c\/strong\u003e\u003cbr\u003eA scan function is available for automatic identification of M-Bus devices and registers discovery.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eEmbedded M-Bus level converter\u003c\/strong\u003e\u003cbr\u003eAn M-Bus level converter is embedded in the gateway, so no external one is required.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKNX standard datapoints (DPTs) support\u003c\/strong\u003e\u003cbr\u003eKNX standard datapoints (DPTs) are supported, guaranteeing a simple KNX device\/system integration.\u003c\/p\u003e\u003cp\u003eM-BUS to KNX TP Gateway - 10 devices INKNXMEB0100000\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732298764546,"sku":"INS1C-29","price":934.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/V6PT_UL_side.avif?v=1792017530"},{"product_id":"inknxlge016o000-lg-vrf-systems-to-knx-interface","title":"INKNXLGE016O000 LG VRF Systems to KNX Interface","description":"\u003cp\u003eLG VRF systems to KNX Interface - 16 uts\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732298928386,"sku":"INS1D-43","price":1796.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/intesis-v6-gateway_side.png?v=1792017533"},{"product_id":"in701knx3k00000-intesis-protocol-translator-with-knx","title":"IN701KNX3K00000 Intesis Protocol Translator with KNX","description":"\u003cp\u003eIntesis protocol translator with KNX, Serial and IP support - 3000 points\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732298895618,"sku":"INS1B-32","price":3961.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/in701knx3k00000.jpg?v=1792017533"},{"product_id":"in775fgl00mo000-fujitsu-ac-interface-with-knx","title":"IN775FGL00MO000 Fujitsu AC Interface with KNX","description":"\u003cp\u003eThe Fujitsu application has been specially designed to allow bidirectional control and monitoring of Fujitsu VRF systems from a KNX installation. The solution allows the integration of up to 64 indoor units from a single interface.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKNX standard datapoints (DPTs) support \u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eKNX standard datapoints (DPTs) are supported, guaranteeing a simple KNX device\/system integration.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDirect access to the outdoor unit\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eConnection is simple, as the interface connects directly to the outdoor unit’s communication bus.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAutomatic identification\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eA scan function is available for automatic identification of the units present in the VRF system.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOutdoor unit signals\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eSignals assigned to the outdoor unit are available to be used in the integration.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIndividual indoor unit energy consumption signals\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eEnergy consumption signals from each indoor unit are available, so they can be checked individually.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDatapoint support\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eA wide range of monitoring and control datapoints is available.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCommissioning-friendly approach with Intesis MAPS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTemplates can be imported and reused as often as needed, significantly reducing commissioning time.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eConfiguration tool and interface automatic updates\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eBoth the Intesis MAPS configuration tool and the interface's firmware can receive automatic updates.\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732298993922,"sku":"INS1D-66","price":3912.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/700_Series_Air_UL_side.avif?v=1792017535"},{"product_id":"inmbspan001i100-panasonic-etherea-ac-units-to-modbus-rtu-interface","title":"INMBSPAN001I100 Panasonic Etherea AC Units to Modbus RTU Interface","description":"\u003cp\u003eModbus RTU - PANASONIC AC. Domestic Line\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732299256066,"sku":"INS1A-80","price":328.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/panasonic-etherea-ac-unit-modbus-rtu-interface.jpg?v=1792017539"},{"product_id":"inknxuni001i000-universal-ir-air-conditioner-to-knx-interface","title":"INKNXUNI001I000 Universal IR Air Conditioner to KNX Interface","description":"\u003cp\u003eKNX - IR interface for generic AC with I\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732299354370,"sku":"INS1A-12","price":295.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/INKNXUNI001I000-img.png?v=1792017541"},{"product_id":"inknxmeb1200000-m-bus-to-knx-tp-gateway","title":"INKNXMEB1200000 M-BUS to KNX TP Gateway","description":"\u003cp\u003e\u003cstrong\u003eEasy commissioning\u003c\/strong\u003e\u003cbr\u003eIntegration and M-BUS commissioning processes are managed via the Intesis MAPS configuration tool.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSupport for KNX TP devices\u003c\/strong\u003e\u003cbr\u003eThe gateway supports KNX TP (twisted pair) devices.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eControl up to 3000 KNX communication objects\u003c\/strong\u003e\u003cbr\u003eUp to 3000 KNX communication objects can be controlled by the gateway.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAutomatic meter detection and register discovery\u003c\/strong\u003e\u003cbr\u003eA scan function is available for automatic identification of M-Bus devices and registers discovery.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eEmbedded M-Bus level converter\u003c\/strong\u003e\u003cbr\u003eAn M-Bus level converter is embedded in the gateway, so no external one is required.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKNX standard datapoints (DPTs) support\u003c\/strong\u003e\u003cbr\u003eKNX standard datapoints (DPTs) are supported, guaranteeing a simple KNX device\/system integration.\u003c\/p\u003e\u003cp\u003eM-BUS to KNX TP Gateway - 120 devices INKNXMEB1200000\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732299616514,"sku":"INS1C-32","price":2393.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/V6PT_UL_side_14cddcd1-b89a-4832-a143-8ed65eda04f4.avif?v=1792017542"},{"product_id":"in7004852500000-intesis-protocol-translator-with-serial-and-ip-support","title":"IN7004852500000 Intesis Protocol Translator with Serial and IP Support","description":"\u003cp\u003eIntesis protocol translator Serial \u0026amp; IP\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732299682050,"sku":"INS1B-34","price":1493.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/Intesis-700-485_9034cc2b-2ff6-4a02-954c-619b2d30293c.jpg?v=1792017544"},{"product_id":"in775fgl00so000-fujitsu-ac-interface-with-knx","title":"IN775FGL00SO000 Fujitsu AC Interface with KNX","description":"\u003cp\u003eThe Fujitsu IN775FGL00SO000 application has been specially designed to allow bidirectional control and monitoring of Fujitsu VRF systems from a KNX installation. The solution allows the integration of up to 16 indoor units from a single interface.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKNX standard datapoints (DPTs) support\u003c\/strong\u003e\u003cbr\u003eKNX standard datapoints (DPTs) are supported, guaranteeing a simple KNX device\/system integration.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDirect access to the outdoor unit\u003c\/strong\u003e\u003cbr\u003eConnection is simple, as the interface connects directly to the outdoor unit’s communication bus.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAutomatic identification\u003c\/strong\u003e\u003cbr\u003eA scan function is available for automatic identification of the units present in the VRF system.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOutdoor unit signals\u003c\/strong\u003e\u003cbr\u003eSignals assigned to the outdoor unit are available to be used in the integration.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIndividual indoor unit energy consumption signals\u003c\/strong\u003e\u003cbr\u003eEnergy consumption signals from each indoor unit are available, so they can be checked individually.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDatapoint support\u003c\/strong\u003e\u003cbr\u003eA wide range of monitoring and control datapoints is available.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCommissioning-friendly approach with Intesis MAPS\u003c\/strong\u003e\u003cbr\u003eTemplates can be imported and reused as often as needed, significantly reducing commissioning time.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eConfiguration tool and interface automatic updates\u003c\/strong\u003e\u003cbr\u003eBoth the Intesis MAPS configuration tool and the interface's firmware can receive automatic updates.\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732299878658,"sku":"INS1D-67","price":2331.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/700_Series_Air_UL_side_81474e2f-8a70-408a-b1de-3c9ad881aaea.avif?v=1792017544"},{"product_id":"inknxlge064o000-lg-vrf-systems-to-knx-interface","title":"INKNXLGE064O000 LG VRF Systems to KNX Interface","description":"\u003cp\u003eLG VRF systems to KNX Interface - 64 uts\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732299944194,"sku":"INS1D-44","price":3370.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/intesis-v6-gateway_side_6c65fbad-fa8c-401e-93b9-a5ef7bc7cde6.png?v=1792017546"},{"product_id":"inmbspan001a000-panasonic-air-to-water","title":"INMBSPAN001A000 Panasonic Air to Water","description":"\u003cp\u003eModbus RTU - PANASONIC Air to Water unit\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732300108034,"sku":"INS1A-83","price":328.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/inmbspan001a000_front_w658.jpg?v=1792017550"},{"product_id":"inknxhai008c000-haier-commercial-vrf-systems-to-knx-interface","title":"INKNXHAI008C000 Haier Commercial \u0026 VRF Systems to KNX Interface","description":"\u003cp\u003e\u003cstrong\u003eETS configuration\u003c\/strong\u003e\u003cbr\u003eThe interface is configured using the ETS standard configuration tool software.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCompatible with all KNX thermostats in the market\u003c\/strong\u003e\u003cbr\u003eAll the required DPT objects to be compatible with all KNX thermostats in the market are available.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSmooth KNX thermostat integration.\u003c\/strong\u003e\u003cbr\u003eKNX thermostats are allowed to control the AC unit via the thermostat's temperature sensor.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTotal unit control and monitoring from KNX\u003c\/strong\u003e\u003cbr\u003eThrough internal variables, running hours counter (for maintenance purposes), and error indication.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC unit control by both remote controller and KNX\u003c\/strong\u003e\u003cbr\u003eThe AC unit can be simultaneously controlled by the manufacturer's remote controller and KNX.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSmall footprint\u003c\/strong\u003e\u003cbr\u003eThe interface can be quickly installed inside the AC unit thanks to its reduced dimensions.\u003c\/p\u003e\u003cp\u003eHaier Commercial \u0026amp; VRF systems to KNX Interface - 8 units INKNXHAI008C000\u003c\/p\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732300566786,"sku":"INS1A-13","price":1504.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/INKNXHAI0XXC000_47d55314-30e8-4667-bdbe-32a60e7f4ccf.avif?v=1792017553"},{"product_id":"inwmpfgl001i000-fujitsu-rac-and-vrf-systems-to-wifi","title":"INWMPFGL001I000 Fujitsu RAC and VRF Systems to WiFi","description":"Wi-Fi - FUJITSU AC Domestic, Commercial. The Fujitsu-ASCII gateway allows a complete and natural integration of Fujitsu RAC and VRF Air Conditioner units into IP based Home Automation Sytems.\n\n\u003cstrong\u003eFEATURES\u003c\/strong\u003e\n\u003cul\u003e\n \t\u003cli\u003eIntuitive web interface for the WiFi configuration.\u003c\/li\u003e\n \t\u003cli\u003eb\/g\/n WiFi standards supported at 2,4 GHz.\u003c\/li\u003e\n \t\u003cli\u003eQuick and easy installation (plug and configure the WiFi).\u003c\/li\u003e\n \t\u003cli\u003eExternal power not required.\u003c\/li\u003e\n \t\u003cli\u003eSimultaneous control of the AC unit by the IR remote controller and by Home Automation systems.\u003c\/li\u003e\n \t\u003cli\u003eIntegration with any IP Home Automation System thanks to our open ASCII protocol.\u003c\/li\u003e\n \t\u003cli\u003eCompatible with the drivers available in Intesis webpage.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Engenuity Systems","offers":[{"title":"Default Title","offer_id":50732300632322,"sku":"INS1D-04","price":328.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/1839\/2578\/files\/INWMPFGL001I000-img.png?v=1792017555"}],"url":"https:\/\/engenuity.com\/collections\/intesis.oembed","provider":"Engenuity Systems","version":"1.0","type":"link"}